LoggerSeriesEvent
LoggerSeriesEvent =
HydrodynamicEventBase&object
Continuous level series recorded by an installed sensor (pressure transducer with datalogger). Not a controlled test and not a static level: it carries no steps or recovery and is not a valid analysis source. Pump state is not stored per reading. Since v2.4.
Type Declaration
aggregation?
optionalaggregation?:ReadingAggregation
none (raw readings), hourly or daily.
barometric_compensation?
optionalbarometric_compensation?:BarometricCompensation
interval?
optionalinterval?:number
Nominal interval between readings, in minutes.
measurement_method?
optionalmeasurement_method?:OpenVocab<MeasurementMethod>
Recommended values: MEASUREMENT_METHODS.
readings
readings:
LoggerReading
At least one reading.
sensor_depth?
optionalsensor_depth?:number
Sensor depth in meters from ground level. A level below it is an invalid reading.
type
type:
"logger_series"